Insulation resistance measurement:
– selected test voltage: 50, 100, 250, 500, 1000 V,
– continuous indication of insulation resistance or leakage current,
– automatic discharge of capacitance of tested object after the insulation resistance measurement,
– acoustic signalling of five-second periods to facilitate obtaining time characteristics,
– indication of actual test voltage during the measurement,
– protection against measuring live objects,
– three-lead measurement.
Continuity measurement of protective and equipotential conductors according to EN 61557 – 4 with the >200 mA current
Low-voltage circuit continuity and resistance measurement:
– circuit resistance measurement (<1999 ) with the <15 mA current,
– quick sound signal if circuit resistance is below 30Ω.
Capacitance measurement during the RISO measurement
Measurement of alternating and direct voltages in the 0…600 V range.
Power supply: 4 AA disposable or rechargeable batteries, monitoring of power supply voltage.
Meter conform to EN 61557.
Electric safety:
type of insulation: double, according to EN 61010 – 1 and IEC 61557
measurement category: IV 600 V (III 1000 V) according to EN 61010 – 1
protection class acc. to EN 60529: IP67
Other technical specifications:
power suply: 4 alkaline batteries or or battery package Ni-MH
weight: ~1 kg
dimentions: 220 x 100 x 60 mm
Insulation resistance measurement
Measuring range according to EN 61557 – 2 for UN=50 V: 50 kΩ…250,0 MΩ
Range
Resolution
Accuracy
0,0…999,9 kΩ
0,1 kΩ
±(3% m.v. + 8 digits)
1,000…9,999 MΩ
0,001 MΩ
10,0…99,99 MΩ
0,01 MΩ
100,0…250,0 MΩ
0,1 MΩ
Measuring range according to EN 61557 – 2 for UN=100 V: 100 kΩ…500,0 MΩ
Range
Resolution
Accuracy
0,0…999,9 kΩ
0,1 kΩ
±(3% m.v. + 8 digits)
1, 000…9,999 MΩ
0,001 MΩ
10,0…99,99 MΩ
0,01 MΩ
100,0…500,0 MΩ
0,1 MΩ
Measuring range according to EN 61557 – 2 for UN=250 V: 250 kΩ…2,000 GΩ
Range
Resolution
Accuracy
0,0…999,9 kΩ
0,1 kΩ
±(3% m.v. + 8 digits)
1,000…9,999 MΩ
0,001 MΩ
10,0…99,99 MΩ
0,01 MΩ
100,0…999,0 MΩ
0,1 MΩ
1,000…2,000 GΩ
0,001 GΩ
Measuring range according to PN-EN 61557 – 2 for UN=500 V: 500 kΩ…5,00 GΩ
Range
Resolution
Accuracy
0,0…999,9 kΩ
0,1 kΩ
±(3% m.v. + 8 digits)
1,000…9,999 MΩ
0,001 MΩ
10,00…99,99 MΩ
0,01 MΩ
100,0…999,0 MΩ
0,1 MΩ
1,000…5,000 GΩ
0,001 GΩ
±(4% m.v. + 6 digits)
Measuring range according to EN 61557 – 2 for UN=1000 V: 1000 kΩ…10,00 GΩ
Range
Resolution
Accuracy
0,0…999,9 kΩ
0,1 kΩ
±(3% m.v. + 8 digits)
1,000…9,999 MΩ
0,001 MΩ
10,00…99,99 MΩ
0,01 MΩ
100,0…999,0 MΩ
0,1 MΩ
1,000…5,000 GΩ
0,001 GΩ
±(4% m.v. + 6 digits)
5,00…10,00 GΩ
0,01 GΩ
Continuity measurement of protective and equipotential conductors with the 200 mA current
Measuring range according to EN 61557 – 4: 0,10…1999 Ω
Range
Resolution
Accuracy
0,00…19,99 Ω
0,01 Ω
±(2% m.v. + 3 digits)
20,0…199,9 Ω
0,1 Ω
200…1999 Ω
1 Ω
±(4% m.v. + 3 digits)
Voltage on open terminals: <8 V
Output current at R <2 Ω: ISC >200 mA: ISC >200 mA
Compensation of test leads’ resistance
Unidirectional current flow
Low-voltage and resistance measurement
Range
Resolution
Accuracy
0,0…199,9 Ω
0,1 Ω
±(3% m.v. + 3 digits)
200…1999 Ω
1 Ω
Voltage on open terminals: <8 V
Current for closed terminals 5 mA < ISC < 15 mA
Sound signal and green LED on when measured resistance < 30 Ω ± 50%
Compensation of test leads’ resistance,
Capacitance measurements
Range
Resolution
Accuracy
1…999 nF
1 nF
±(5% m.v. + 5 digits)
1,00…9,99µF
0,01µF
Capacitance value displayed during the RISO measurement
For test voltages below 100 V and measured resistance below 10 MΩ, unspecified capacitance measurement error
MIC-10 Insulation Resistance Meter WMGBMIC10
Description
– selected test voltage: 50, 100, 250, 500, 1000 V,
– continuous indication of insulation resistance or leakage current,
– automatic discharge of capacitance of tested object after the insulation resistance measurement,
– acoustic signalling of five-second periods to facilitate obtaining time characteristics,
– indication of actual test voltage during the measurement,
– protection against measuring live objects,
– three-lead measurement.
– circuit resistance measurement (<1999 ) with the <15 mA current,
– quick sound signal if circuit resistance is below 30Ω.
Electric safety:
Other technical specifications:
Insulation resistance measurement
Measuring range according to EN 61557 – 2 for UN=50 V: 50 kΩ…250,0 MΩ
Measuring range according to EN 61557 – 2 for UN=100 V: 100 kΩ…500,0 MΩ
Measuring range according to EN 61557 – 2 for UN=250 V: 250 kΩ…2,000 GΩ
Measuring range according to PN-EN 61557 – 2 for UN=500 V: 500 kΩ…5,00 GΩ
Measuring range according to EN 61557 – 2 for UN=1000 V: 1000 kΩ…10,00 GΩ
Continuity measurement of protective and equipotential conductors with the 200 mA current
Measuring range according to EN 61557 – 4: 0,10…1999 Ω
Low-voltage and resistance measurement
Capacitance measurements
Measurement of alternating and direct voltage