DC current measurement (CMP-401 only) and AC current.
AC/DC voltage measurement up to 600 V.
Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 50.
Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Diode test.
Additionally:
- safe, insulated measuring clamps,
- double molded housing,
- autoranging/manual range selection,
- DATA HOLD function, for holding measured values,
- backlit LCD,
- REL function,
- over range indication,
- AUTO-OFF function.
Temperature measurement
-20,0…760°C |
±(3% m.v. + 5°C) |
-4,0…1400°F |
±(3% m.v. + 9°F) |
*probe (K type) accuracy not included
Frequency measurement
-10 Hz |
±(1,5% m.v. + 2 dgt) |
- sensitivity: 100 V(<50 Hz), 50 V(50…400 Hz); 15 V(401 Hz…10 kHz)
AC current measurement
4,000 A |
0,001 A |
±(2,5% m.v. + 12 dgt) |
40,00 A |
0,01 A |
±(2,5% m.v. + 8 dgt) |
400,0 A |
0,1 A |
±(2,8% m.v. + 8 dgt) |
- frequency range: 50…60 Hz.
AC voltage measurement
400,0 mV |
0,1 mV |
no range |
4,000 V |
0,001 V |
±(1,8% m.v. + 8 dgt) |
40,00 V |
0,01 V |
400,0 V |
0,1 V |
600,0 V |
0,1 V |
±(2,5% m.v. + 8 dgt) |
- frequency range: 50 Hz…400 Hz
DC voltage measurement
400,0 mV |
0,1 mV |
±(0,8% m.v. + 2 dgt) |
4,000 V |
0,001 V |
±(1,5% m.v. + 2 dgt) |
40,00 V |
0,01 V |
400,0 V |
0,1 V |
600,0 V |
0,1 V |
±(2% m.v. + 2 dgt) |
Resistance measurement
400,0 Ω |
0,1 Ω |
±(1,0% m.v + 4 dgt) |
4,000 kΩ |
0,001 kΩ |
±(1,5% m.v. + 2 dgt) |
40,00 kΩ |
0,01 kΩ |
400,0 kΩ |
0,1 kΩ |
4,000 MΩ |
0,001 MΩ |
±(2,5% m.v. + 3 dgt) |
40,00 MΩ |
0,01 MΩ |
±(3,5% m.v. + 5 dgt) |
„m.v.”- measured value
Electric security:
– measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
– protection class acc. to EN 60529: IP40
Other technical data:
– power supply: 9 V battery type 6LR61
– display: 4000 counts, backlit LCD
– continuity test: I<0,5 mA, sound signal for R<50 Ω
– diode test: I=0,3 mA, U0 = 1,5 V DC
– over range indication: 0L displayed
– sampling rate: 2 times per second
– input impedance: 10 MΩ (V DC and V AC)
– clamp size: opening 30 mm (1,2”)
– auto power OFF: approx. 30 min.
– dimensions: 197 x 70 x 40 mm
– weight: 183 g
– accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
– quality standard ISO 9001
Rated operational conditions:
– operating temperature: 0…+40°C
– storage temperature: -20…+60°C
– operating humidity: max 80% up to 31°C
decreasing linearly to 50% at 40°C
– operating altitude: max 2000 m
CMP-400 Digital Clamp-On Multimeter WMXXCMP400
Description
DC current measurement (CMP-401 only) and AC current.
Resistance measurement and continuity test:
Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Diode test.
Additionally:
Temperature measurement
*probe (K type) accuracy not included
Frequency measurement
AC current measurement
AC voltage measurement
DC voltage measurement
Resistance measurement
„m.v.”- measured value
Electric security:
– measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
– protection class acc. to EN 60529: IP40
Other technical data:
– power supply: 9 V battery type 6LR61
– display: 4000 counts, backlit LCD
– continuity test: I<0,5 mA, sound signal for R<50 Ω
– diode test: I=0,3 mA, U0 = 1,5 V DC
– over range indication: 0L displayed
– sampling rate: 2 times per second
– input impedance: 10 MΩ (V DC and V AC)
– clamp size: opening 30 mm (1,2”)
– auto power OFF: approx. 30 min.
– dimensions: 197 x 70 x 40 mm
– weight: 183 g
– accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
– quality standard ISO 9001
Rated operational conditions:
– operating temperature: 0…+40°C
– storage temperature: -20…+60°C
– operating humidity: max 80% up to 31°C
decreasing linearly to 50% at 40°C
– operating altitude: max 2000 m
Related products
CMP-1006 Digital Clamp-on Multimeter WMXXCMP1006
Read moreSonel MMR-630
Read moreCMM-40 Industrial Multimeter WMXXCMM40
Read more